Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket 1.81
Carrier

OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA024060AEKA

SKU: CARRIE-PG9MAA024060AEKA-PRESSURE_SWITCH-HK06NB124 Brand: Carrier
Guaranteed to fit PG9MAA024060AEKA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket (HK06NB124) for Model PG9MAA024060AEKA

This is the factory OEM replacement pressure switch with mounting bracket for the Carrier PG9MAA024060AEKA gas furnace. The pressure switch is a safety device that monitors negative pressure created by the inducer motor to confirm proper venting before allowing the ignition sequence to proceed. When this switch fails or its hose becomes cracked or clogged, the furnace will lock out on a pressure switch fault — typically indicated by a flashing LED error code — leaving you with no heat until the issue is resolved.

  • Specs: 1.81" W.C. set point | SPST (Single-Pole, Single-Throw) | Includes OEM mounting bracket | Replaces obsolete part numbers HK06NB119, HK06NB120, and HK06NB122
  • OEM vs Generic: This OEM switch is factory-calibrated to the exact W.C. set point required by the PG9MAA024060AEKA. Aftermarket switches often carry wider tolerances that can cause nuisance lockouts or — more dangerously — fail to detect a true venting fault.
  • Install difficulty: 2/5 — Turn off gas and power before servicing. Tools needed: 1/4" nut driver, flathead screwdriver, and needle-nose pliers. Inspect the rubber hose for cracks before reusing it. Photograph existing wiring and hose routing before removal.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG9MAA024060AEKA gas furnace. This part supersedes HK06NB119, HK06NB120, and HK06NB122 and fits over 200 Carrier and Bryant residential furnace models — always verify the W.C. rating on your existing switch or unit data plate before ordering. Have questions about fitment? Our HVAC parts specialists verify compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA024060AEKA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA024060AEKA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket 1.81" WC — PG9MAA024060AEKA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.