Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Board HK42FZ066 for PG96VAT60080CCAA
Carrier

OEM Carrier Furnace Control Board HK42FZ066 for PG96VAT60080CCAA

SKU: CARRIE-PG96VAT60080CCAA-CONTROL_BOARD-HK42FZ066 Brand: Carrier
Guaranteed to fit PG96VAT60080CCAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Control Board HK42FZ066 for Model PG96VAT60080CCAA

This is the OEM Carrier integrated furnace control (IFC) board, part number HK42FZ066, factory-specified for the Carrier PG96VAT60080CCAA 96% AFUE two-stage gas furnace. The control board is the brain of your furnace — it sequences every heating cycle, monitors safety inputs from the pressure switch, flame sensor, and limit switches, manages inducer and blower motor timing, and generates diagnostic fault codes when something goes wrong. When this board fails, you may experience a complete no-heat lockout, repeated ignition attempts with no flame establishment, erratic blower behavior, or a board that simply powers off mid-cycle with no fault code output.

  • Part Number & Specs: OEM Part # HK42FZ066 (superseded by HK42FZ094) | 24V control circuit | Compatible with single- and two-stage gas valve configurations | Onboard LED fault-code diagnostics | Factory board number CEBD431102-04-RA
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Parts control board — not an aftermarket clone. OEM boards carry pre-programmed timing sequences calibrated to your specific furnace model, ensuring proper ignition trial timing, blower off-delay, and safety lockout thresholds. Aftermarket boards frequently exhibit mistimed sequences that stress igniters and shorten heat exchanger life.
  • Install Difficulty: 4/5 — This is an intermediate-to-advanced repair. Tools required: #2 Phillips and flathead screwdrivers, needle-nose pliers, smartphone or camera for wiring documentation, and a multimeter for pre/post-install voltage verification. Always disconnect power at the breaker AND set the furnace switch to OFF before beginning. Photograph all wiring harness connections before removal. Static discharge precautions (anti-static wrist strap) are strongly recommended.
  • Warranty: 1-year OEM manufacturer warranty from date of purchase. Ships same business day from our warehouse when ordered before cutoff.

Compatibility Note: Designed for the Carrier PG96VAT60080CCAA 96% AFUE two-stage gas furnace. Note that OEM part HK42FZ066 has been superseded by HK42FZ094 — both are genuine Carrier OEM boards and fulfill the same factory specification for this model. Always verify your existing board's part number on the board label before ordering. Our fitment team is available to confirm compatibility before you purchase — no heat, no wait.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG96VAT60080CCAA?
Yes. This is the factory-specified OEM control board for the Carrier PG96VAT60080CCAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG96VAT60080CCAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online