Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor w/Lead LH680534 for PG95XAT60100CAAA
OEM Carrier Flame Sensor w/Lead LH680534 for PG95XAT60100CAAA
OEM Carrier Flame Sensor w/Lead LH680534 for PG95XAT60100CAAA
OEM Carrier Flame Sensor w/Lead LH680534 for PG95XAT60100CAAA
Carrier

OEM Carrier Flame Sensor w/Lead LH680534 for PG95XAT60100CAAA

SKU: CARRIE-PG95XAT60100CAAA-FLAME_SENSOR-LH33WZ521 Brand: Carrier
Guaranteed to fit PG95XAT60100CAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor LH680534 (Replaces LH33WZ521) for Model PG95XAT60100CAAA

This is the genuine OEM Carrier flame sensor with lead wire, part number LH680534, the current factory-authorized successor to the discontinued LH33WZ521. It is the direct, drop-in replacement for the Carrier PG95XAT60100CAAA 95% AFUE single-stage gas furnace. The flame sensor is a safety-critical component: a small rod that sits in the burner flame and passes a microamp signal back to the control board to confirm ignition. When the sensor becomes coated with oxidation or fails outright, the control board cannot verify flame presence and shuts the gas valve down within 5–8 seconds of ignition — causing the frustrating symptom of a furnace that lights briefly, then immediately locks out.

  • Part Numbers: OEM Part # LH680534 | Supersedes discontinued # LH33WZ521 | Includes pre-attached lead wire pigtail for direct plug-in connection
  • OEM vs Generic: This is a genuine Carrier factory part — not an aftermarket substitute. OEM sensors are manufactured to exact microamp tolerance specs. Aftermarket flame sensors often fall outside acceptable current range, triggering nuisance lockouts or masking a true wiring/board fault.
  • Install Difficulty: 1/5 — One of the easiest furnace repairs. Turn off power and gas, remove the single 1/4" hex-head screw securing the sensor bracket, unplug the lead connector, and reverse to install. Tools: 1/4" nut driver or flathead screwdriver. Estimated time: 10–15 minutes.
  • Warranty: 1-year OEM manufacturer's warranty against defects. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PG95XAT60100CAAA 95% AFUE gas furnace. Also fits a wide range of Carrier, Bryant, and Payne high-efficiency furnace models that originally specified LH33WZ521 or LH680534. Always verify against your unit's data plate and wiring diagram before ordering. Not sure it fits? Our parts specialists confirm fitment before you buy — call or chat today. In stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PG95XAT60100CAAA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PG95XAT60100CAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PG95XAT60100CAAA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online