Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Integrated Furnace Control Board HK42FZ040 — PG95XAT60100C
Carrier

OEM Carrier Integrated Furnace Control Board HK42FZ040 — PG95XAT60100C

SKU: CARRIE-PG95XAT60100CAAA-CONTROL_BOARD-HK42FZ040 Brand: Carrier
Guaranteed to fit PG95XAT60100C — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Integrated Furnace Control Board HK42FZ040 for Model PG95XAT60100CAAA

This is the genuine OEM Carrier Integrated Furnace Control Board (part number HK42FZ040), factory-specified for the Carrier PG95XAT60100CAAA 95% AFUE gas furnace. The IFC board is the operational brain of your furnace — it sequences every stage of the heating cycle, from inducer startup and hot surface ignition through gas valve firing, flame verification, and blower ramp-up. When it fails, symptoms range from hard lockout with a flashing fault code and no heat, to erratic short-cycling, blower that runs continuously, or a furnace that starts normally then shuts down mid-cycle. Replacing with a genuine OEM board restores factory-programmed timing, safety thresholds, and diagnostic fault code behavior that aftermarket boards often cannot fully replicate.

  • OEM Part Number: HK42FZ040 | Cross-reference board numbers: CEPL130948-02, CEBD430948-07A | Factory Authorized Part for Carrier PG95XAT60100CAAA
  • OEM vs Generic: Genuine Carrier OEM boards carry factory-programmed algorithms for ignition timing, fan delay, and multi-speed blower sequencing. Generic replacements may use approximated timing that shortens heat exchanger life and can void equipment warranties.
  • Install Difficulty: 3/5 — Turn off power and gas before beginning. Label all wire harness connectors prior to removal; take photos of the existing board. Tools needed: 1/4" nut driver, needle-nose pliers, phone camera. Transfer fuses from old board to new. Restore power and confirm fault code LED is clear before relighting.
  • Warranty: 1-year OEM factory warranty against manufacturing defects. Ships same business day from our climate-controlled warehouse in original Carrier packaging.

Compatibility: Direct OEM replacement for the Carrier PG95XAT60100CAAA 95% AFUE, 100,000 BTU two-stage gas furnace. Also fits select Bryant and Payne models sharing the HK42FZ040 board specification — verify your unit's data plate and existing board part number before ordering. Our HVAC parts specialists are available to confirm fitment. Order now — in stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ040 — PG95XAT60100C?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Integrated Furnace Control Board HK42FZ040 — PG95XAT60100C. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ040 — PG95XAT60100C?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart