This factory OEM dual pressure switch assembly (part HK06NB020) is the direct-fit replacement for the Carrier PG95XAT60080CAAA 95% AFUE two-stage gas furnace. The pressure switch is a safety device that monitors negative pressure generated by the inducer (draft) motor to confirm proper venting before allowing the ignition sequence to proceed. A failed pressure switch is one of the most common causes of furnace lockout — the board detects an open switch circuit and halts all ignition attempts, leaving your home without heat. If your furnace is faulting before the igniter ever glows, or you're getting a pressure switch fault code on the control board, this assembly is the primary suspect.
This listing includes compatibility with supplemental gas pressure switch HK02LB008, a secondary LP/propane gas pressure switch used in some PG95X configurations.
Compatibility: Designed for the Carrier PG95XAT60080CAAA 95% AFUE two-stage packaged gas furnace. Also cross-references successor part HK06MB020 where applicable. Verify your unit's data plate BTU input, staging, and fuel type before ordering — LP/propane variants may require the companion switch HK02LB008. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.