Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch 0.68
Carrier

OEM Carrier Dual Pressure Switch 0.68"/0.34" WC — PG95XAT30040ABAA

SKU: CARRIE-PG95XAT30040ABAA-PRESSURE_SWITCH-HK06NB012 Brand: Carrier
Guaranteed to fit PG95XAT30040ABAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB012 for Model PG95XAT30040ABAA

This OEM Dual Pressure Switch Assembly (part # HK06NB012) is the factory-specified replacement for the Carrier PG95XAT30040ABAA 95% AFUE gas furnace. The dual pressure switch monitors the negative pressure (vacuum) produced by the inducer draft motor to confirm safe flue venting conditions before allowing ignition to proceed. When either switch fails — or inducer vacuum falls outside specification — the furnace control board receives no "proof" signal and locks out on a pressure switch fault code, leaving you with no heat. Common failure symptoms include a flashing fault code indicating an open pressure switch, the inducer running continuously with no ignition attempt, or intermittent lockouts during cold weather when vent restriction increases.

  • Specs: Dual switch assembly | Low-pressure switch (LPS): 0.68" W.C. | Second switch: 0.34" W.C. | SPST normally open contacts | Two wire terminals and one hose port per switch | Factory-matched trip points
  • OEM vs Generic: OEM switches are factory-calibrated to exact W.C. trip points for the PG95XAT30040ABAA. Aftermarket switches with loose tolerances can cause nuisance lockouts or — more dangerously — fail to detect a blocked flue, creating a carbon monoxide risk.
  • Install difficulty: 2/5 — Shut off gas and 120V power before servicing. Tools needed: 1/4" and 5/16" nut drivers, flathead screwdriver, needle-nose pliers, manometer (recommended). Photograph all hose routing before disconnecting. Check rubber pressure hoses for cracks or blockages as a blocked hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before 3PM local time.

Compatibility: Designed for the Carrier PG95XAT30040ABAA 95% AFUE packaged gas furnace. Also replaces cross-reference part numbers BA20266-2 and superseded OEM part HK06MB012. Always verify W.C. ratings on your unit's wiring diagram before ordering — incorrect switch trip points will cause persistent lockout faults. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch 0.68"/0.34" WC — PG95XAT30040ABAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch 0.68"/0.34" WC — PG95XAT30040ABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch 0.68"/0.34" WC — PG95XAT30040ABAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online