Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM dual pressure switch assembly is the factory-specified replacement for the Carrier PG95XAT30040AAAA 95% AFUE gas furnace. The kit includes both the HK06NB012 Dual Pressure Switch Assembly and the HK02LB008 Gas Pressure Switch, covering the complete inducer-proving circuit. These switches are normally-open safety devices that close only when the inducer motor creates the correct negative pressure (vacuum) in the flue system — confirming safe combustion airflow before allowing ignition to proceed. If either switch fails or a hose cracks, the control board will lock out the furnace before a single spark is attempted. Typical symptoms include a blinking fault code for "pressure switch stuck open," no ignition after inducer start, or a furnace that runs the inducer but shuts off within 30 seconds.
Compatibility: Engineered and factory-matched for the Carrier PG95XAT30040AAAA 95% AFUE, single-stage, 40,000 BTU packaged gas furnace. Verify your model number on the unit data plate before ordering. Cross-references: HK06NB012 superseded by HK06MB012; HK02LB008 also referenced as GFS3451-4036. Our fitment team is available to confirm compatibility before you order — order by 3 PM and ships today.