OEM Carrier Flame Sensor LH680534 (Replaces LH33WZ521) for Model PG95SAS60080CBAA

This is the factory OEM replacement flame sensor for the Carrier PG95SAS60080CBAA 95% AFUE gas furnace. The flame sensor — also called a flame rod or flame detector — is a safety component that continuously monitors the burner to confirm that gas has successfully ignited. When it detects a flame, it sends a small microamp signal back to the control board to keep the gas valve open. A failed or contaminated flame sensor causes the furnace to light briefly, then shut down after just 5–8 seconds, typically triggering a lockout fault. This is one of the most common furnace service calls in the field.

  • OEM Part Numbers: LH680534 (current/superseding) | LH33WZ521 (original, now discontinued) — both are covered by this listing. Includes pre-attached lead wire for direct plug-in installation.
  • OEM vs Generic: This is a genuine Carrier factory part, meeting exact microamp output and porcelain insulator tolerances. Aftermarket sensors can exhibit inconsistent signal output, causing nuisance lockouts even after installation.
  • Install Difficulty: 1/5 — One of the easiest furnace repairs. Tools needed: 1/4" hex driver or nut driver. Turn off power and gas before servicing. Locate the sensor in the burner box, disconnect the lead wire, remove the single mounting screw, and reverse to install. Do not touch the rod with bare hands — skin oil degrades signal quality.
  • Warranty: 1-year OEM manufacturer warranty against defects. Ships same business day from our warehouse when ordered by 3:00 PM local time.

Compatibility: Designed for the Carrier PG95SAS60080CBAA 80,000 BTU, 95% AFUE single-stage gas furnace. Also cross-compatible with select Carrier, Bryant, and Payne furnace models that originally specified LH33WZ521 or LH680014. Verify your existing part number on the sensor body or unit wiring diagram before ordering. Our parts specialists are available to confirm fitment — contact us before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PG95SAS60080CBAA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PG95SAS60080CBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PG95SAS60080CBAA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.