OEM Carrier Dual Pressure Switch Assembly HK06NB020 for Model PG95SAS60080CAAA

This OEM dual pressure switch assembly is the factory-specified replacement for the Carrier PG95SAS60080CAAA 95% AFUE gas furnace. The pressure switch proves that the inducer motor has established proper draft before allowing the ignition sequence to begin. When it fails or sticks open, the control board detects an unsafe draft condition and locks out the furnace — often before a single ignition attempt is made. Symptoms include a furnace that runs the inducer but never advances to ignition, a flashing fault code for open pressure switch, or intermittent no-heat calls that reset after power cycling.

  • OEM Part Numbers: HK06NB020 (Dual Pressure Switch Assembly) | HK02LB008 (Gas Pressure Switch) — both covered by this listing. Verify your unit's data plate before ordering.
  • OEM vs Generic: OEM switches are factory-calibrated to the exact water column (W.C.) rating required by the PG95SAS60080CAAA heat exchanger and inducer assembly. Off-brand switches with loose W.C. tolerances can allow unsafe ignition conditions or cause nuisance lockouts.
  • Install Difficulty: 3/5 — Turn off power and gas before starting. Tools needed: 1/4" nut driver, needle-nose pliers, manometer (recommended to verify W.C. after replacement), and a multimeter to confirm switch continuity. Always inspect the rubber hose port and tubing for cracks or blockages before installing the new switch, as a failed hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse — order by 3 PM local time.

Compatibility: Designed for the Carrier PG95SAS60080CAAA 95% AFUE gas furnace. Cross-references: HK06NB020, HK02LB008. If you are unsure which pressure switch applies to your specific unit configuration, contact our fitment team before ordering — we verify compatibility at no charge. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG95SAS60080CAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG95SAS60080CAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG95SAS60080CAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.