Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG95SAS30040AAAA
Carrier

OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG95SAS30040AAAA

SKU: CARRIE-PG95SAS30040AAAA-PRESSURE_SWITCH-HK06NB012 Brand: Carrier
Guaranteed to fit PG95SAS30040AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB012 for Model PG95SAS30040AAAA

This OEM Dual Pressure Switch Assembly (part number HK06NB012, also cross-referenced as HK02LB008) is the factory-specified replacement for the Carrier PG95SAS30040AAAA 95% AFUE gas furnace. The pressure switch is a critical safety component that monitors the negative pressure (vacuum) created by the inducer draft motor before allowing the ignition sequence to proceed. When a pressure switch fails, the furnace will lock out before lighting — you may see a blinking error code, hear the inducer run but the burners never ignite, or experience repeated no-heat calls that reset only temporarily.

  • Specs: Dual pressure switch assembly | Two SPST switches included, each with 2 wire terminals and one hose port | Factory-calibrated W.C. (water column) set points matched to the PG95SAS30040AAAA inducer | Replaces OEM part numbers HK06NB012 and HK02LB008
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact W.C. set points for your specific model. Generic switches often carry wider tolerances that can cause nuisance lockouts in cold weather or, worse, allow unsafe flue conditions that a properly rated switch would catch.
  • Install difficulty: 3/5 — Shut off power and gas before beginning. Tools needed: 1/4" nut driver, flathead screwdriver, needle-nose pliers, manometer (recommended to verify W.C. after install). Carefully label or photograph each hose port connection before removal — incorrect hose routing is the #1 cause of post-repair lockouts.
  • Warranty: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Engineered for Carrier model PG95SAS30040AAAA 95% AFUE packaged gas furnace. This assembly is also compatible with a wide range of Carrier, Bryant, and Payne furnace models that share the HK06NB012 specification — verify your model number and existing hose routing before ordering. Our fitment team is available to confirm compatibility before you buy. Order today and get same-day shipping on in-stock parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG95SAS30040AAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG95SAS30040AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG95SAS30040AAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online