OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SCS48100CAAA
Carrier

OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SCS48100CAAA

SKU: CARRIE-PG92SCS48100CAAA-PRESSURE_SWITCH-HK06NB012 Brand: Carrier
Guaranteed to fit PG92SCS48100CAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB012 for Model PG92SCS48100CAAA

This OEM dual pressure switch assembly (part number HK06NB012) is the factory-specified replacement for the Carrier PG92SCS48100CAAA 92% AFUE gas furnace. The pressure switch is a critical safety component that monitors the negative pressure (vacuum) created by the inducer draft motor to confirm safe flue venting conditions before allowing ignition to proceed. A failed pressure switch causes a hard lockout before ignition — the inducer will run, but the furnace will never reach the ignition stage, resulting in a no-heat call. Secondary part number HK02LB008 (Gas Pressure Switch) is also covered by this assembly listing for LP/propane-configured units.

  • Part Numbers: HK06NB012 (Dual Pressure Switch Assembly) | HK02LB008 (Gas/LP Pressure Switch) | Direct replacement: HK06MB012
  • OEM vs Generic: OEM switches are factory-calibrated to exact water column (W.C.) setpoints for the PG92SCS48100CAAA. Generic alternatives risk nuisance lockouts or — more dangerously — allowing operation under unsafe flue conditions due to W.C. tolerance drift.
  • Install Difficulty: 3/5 — Inducer must be confirmed non-running before servicing. Tools needed: multimeter (continuity test), 1/4" nut driver, needle-nose pliers, manometer (recommended for W.C. verification). Always check hose and port connections for cracks during replacement.
  • Warranty: 1-year OEM factory warranty. In stock — ships same business day from our warehouse.

Compatibility: Engineered to fit the Carrier PG92SCS48100CAAA 92% efficient packaged gas furnace series. Verify the W.C. rating on your existing switch before ordering. Our parts specialists are available to confirm fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SCS48100CAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SCS48100CAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SCS48100CAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.