This OEM Dual Pressure Switch Assembly (part number HK06NB020, superseded by HK06MB020) is the factory-specified replacement for the Carrier PG92SCS48080BAAA 92% AFUE gas furnace. The pressure switch monitors negative pressure created by the inducer draft motor to verify safe venting conditions before the ignition sequence is allowed to proceed. When this switch fails or sticks open, the control board cannot confirm proper draft, causing the furnace to lock out before a flame is ever established — leaving you with no heat. A faulty pressure switch is one of the most common causes of a furnace that runs the inducer but never ignites.
Compatibility: Designed for the Carrier PG92SCS48080BAAA 92% AFUE packaged gas furnace. This assembly replaces both the HK06NB020 Dual Pressure Switch and the HK02LB008 Gas Pressure Switch on applicable configurations. Always verify the W.C. rating on your existing switch label before ordering. Our fitment team is available to confirm compatibility — reach out before you buy.