Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch Kit HK06NB012 — PG92SBS66100CBAA
Carrier

OEM Carrier Dual Pressure Switch Kit HK06NB012 — PG92SBS66100CBAA

SKU: CARRIE-PG92SBS66100CBAA-PRESSURE_SWITCH-HK06NB012 Brand: Carrier
Guaranteed to fit PG92SBS66100CBAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB012 & HK02LB008 for Model PG92SBS66100CBAA

This OEM pressure switch kit is the factory-specified replacement for the Carrier PG92SBS66100CBAA 92% AFUE packaged gas furnace. The kit includes two critical safety switches: the HK06NB012 Dual Air Pressure Switch Assembly, which proves that the inducer motor is running at the correct RPM and generating sufficient draft vacuum before allowing ignition, and the HK02LB008 Gas Pressure Switch, which monitors gas line pressure to ensure safe combustion conditions. When either switch fails, the furnace control board will lock out ignition — typically displaying a fault code and resulting in no heat. Common failure symptoms include the inducer motor running but ignition never initiating, or the furnace cycling off within seconds of startup.

  • Kit Includes: HK06NB012 Dual Air Pressure Switch Assembly + HK02LB008 Gas Pressure Switch | Both switches include 2 wire terminals and one hose port each | Factory-matched W.C. (water column) setpoints for model PG92SBS66100CBAA
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact W.C. trip points. Aftermarket substitutes often carry wider tolerances, risking nuisance lockouts or — more critically — failing to detect a true inducer fault, which can allow unsafe flue gas conditions.
  • Install Difficulty: 3/5 — Turn off gas supply and 120V power before servicing. Tools needed: 1/4" & 5/16" nut drivers, needle-nose pliers, manometer (recommended to verify W.C. after install). Photograph all hose and wiring connections before disconnecting. Clear any fault codes after installation.
  • Warranty: 1-year OEM factory warranty on both switches. Orders placed before 3 PM local time ship same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier PG92SBS66100CBAA packaged gas furnace. Always verify your unit's existing switch W.C. ratings on the data plate or wiring diagram before ordering. Not sure if this fits? Our HVAC parts specialists confirm fitment before you buy — call or chat now.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Kit HK06NB012 — PG92SBS66100CBAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Kit HK06NB012 — PG92SBS66100CBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Kit HK06NB012 — PG92SBS66100CBAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online