Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SBS66100CAAA
Carrier

OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SBS66100CAAA

SKU: CARRIE-PG92SBS66100CAAA-PRESSURE_SWITCH-HK06NB012 Brand: Carrier
Guaranteed to fit PG92SBS66100CAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB012 for Model PG92SBS66100CAAA

This OEM Dual Pressure Switch Assembly (part #HK06NB012) is the factory-specified replacement for the Carrier PG92SBS66100CAAA packaged gas furnace. The pressure switch is a critical safety component that monitors the negative pressure (vacuum) created by the inducer motor, confirming that combustion gases are being properly vented before allowing the ignition sequence to proceed. When this switch fails or sticks open, the furnace control board will lock out ignition entirely — leaving you with a blinking fault code, no heat, and a furnace that clicks through a cycle without lighting. This assembly also includes the secondary gas pressure switch (HK02LB008), ensuring the complete dual-switch circuit is restored with a single repair.

  • Specs: Dual pressure switch assembly | Includes both air-proving and gas pressure switch | 2-wire terminals per switch | Single hose port per switch | Factory-matched W.C. (water column) rating for PG92SBS66100CAAA
  • OEM vs Generic: OEM switches are calibrated to the precise W.C. setpoint required by the Carrier PG92SBS66100CAAA. Aftermarket switches often carry wider pressure tolerances, risking nuisance lockouts or — more dangerously — failing to detect a true venting fault.
  • Install difficulty: 2/5 — Shut off gas and power before beginning. Tools needed: flat-head screwdriver, needle-nose pliers, manometer (recommended to verify W.C. after install). Label all hose ports and wiring before disconnecting. The inducer housing must be accessible; no refrigerant handling required.
  • Warranty: 1-year OEM factory warranty included. Orders placed before 3 PM ship same business day from our warehouse.

Compatibility: Engineered for the Carrier PG92SBS66100CAAA packaged gas furnace. This listing covers both OEM part numbers HK06NB012 (Dual Pressure Switch Assembly) and HK02LB008 (Gas Pressure Switch) as included in the assembly. Always verify your unit's model data plate and existing switch W.C. rating before installation. Our fitment team is available to confirm compatibility — order with confidence or contact us before purchasing.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SBS66100CAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SBS66100CAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB012 — PG92SBS66100CAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online