Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG92SBS60080CBAA
Carrier

OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG92SBS60080CBAA

SKU: CARRIE-PG92SBS60080CBAA-PRESSURE_SWITCH-HK06NB020 Brand: Carrier
Guaranteed to fit PG92SBS60080CBAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Dual Pressure Switch Assembly HK06NB020 for Model PG92SBS60080CBAA

This OEM Dual Pressure Switch Assembly (part number HK06NB020) is the factory-specified replacement for the Carrier PG92SBS60080CBAA 92% AFUE gas furnace. The pressure switch is a safety device that monitors negative pressure (draft) created by the inducer motor — it must close before the ignition sequence can begin. When this switch fails or sticks open, the control board reads a fault and locks out the furnace before a single spark fires, leaving you with a no-heat call. Common symptoms include a flashing fault code for "pressure switch stuck open," a furnace that starts the inducer but never advances to ignition, or intermittent heating on cold, windy days when flue back-pressure fluctuates.

  • Part Numbers: Primary OEM part HK06NB020 (Dual Pressure Switch Assembly) | Secondary OEM part HK02LB008 (Gas Pressure Switch) — both are factory-authorized Carrier components for this assembly.
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact water column (W.C.) trip points for the PG92SBS60080CBAA's inducer and heat exchanger. Generic switches often carry ±10–15% W.C. tolerances, risking nuisance lockouts or — more dangerously — failure to detect a cracked heat exchanger.
  • Install Difficulty: 3/5 — Shut off gas and power before starting. Tools needed: 1/4" nut driver, flat-head screwdriver, manometer or U-tube to verify W.C. rating, and a multimeter to confirm continuity after install. Check all rubber hose ports for cracks before reconnecting; a leaking hose will cause the same fault code as a failed switch.
  • Warranty: 1-year OEM factory warranty. In-stock units ship same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered for Carrier PG92SBS60080CBAA packaged gas furnace systems. Always verify the W.C. rating printed on your existing switch before ordering — a mismatched trip point will cause either a no-heat lockout or an unsafe bypass of the proving circuit. Have your model and serial number ready and our fitment team will confirm compatibility before you check out.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG92SBS60080CBAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG92SBS60080CBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Dual Pressure Switch Assembly HK06NB020 — PG92SBS60080CBAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.