Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA
OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA
OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA
OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA
Carrier

OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA

SKU: CARRIE-PG92SBS48100CAAA-FLAME_SENSOR-LH33WZ521 Brand: Carrier
Guaranteed to fit PG92SBS48100CAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor LH680534 / LH33WZ521 for Model PG92SBS48100CAAA

This is the genuine OEM Carrier flame sensor — part number LH680534 (with lead wire), the current factory replacement for the superseded LH33WZ521 — designed for the Carrier PG92SBS48100CAAA packaged gas furnace. The flame sensor is a safety-critical component: a small rod positioned in the burner flame that passes a micro-amp current through the flame to prove ignition. When it fails — typically due to oxidation or carbon buildup on the sensing rod — the control board cannot confirm a lit burner and will shut off the gas valve within 5–8 seconds, causing the frustrating symptom of a furnace that lights briefly, then immediately shuts down and locks out.

  • Part Numbers: LH680534 (primary, with lead wire) | LH33WZ521 (superseded OEM number — LH680534 is the direct factory replacement)
  • OEM vs Generic: This is a genuine Carrier factory part with the pre-attached lead wire included (LH680534), ensuring exact connector fit and factory-spec rod geometry. Generic sensors often feature incorrect rod length or bracket angles that cause nuisance lockouts even after installation.
  • Install Difficulty: 2/5 — Turn off power and gas before beginning. Tools needed: 1/4" hex driver or nut driver, needle-nose pliers. Disconnect the lead wire, remove the single mounting screw, swap the rod, reconnect the lead. Always verify micro-amp reading (1.5–4 µA typical) with a multimeter on initial startup.
  • Warranty: 1-year OEM manufacturer warranty. In-stock orders ship same business day from our warehouse.

Compatibility: Designed for the Carrier PG92SBS48100CAAA packaged gas unit. Also fits select Carrier, Bryant, and Payne furnace models including the PG92SBS and PG92SCS series. Verify your model and data plate before ordering — our team is available to confirm fitment. Order today and get back to heat fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA?
Yes. This is the factory-specified OEM flame sensor for the Carrier OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier OEM Carrier Flame Sensor w/Lead LH680534 / LH33WZ521 — PG92SBS48100CAA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR