Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket 0.33 WC for PG8UAA060155ACJA
Carrier

OEM Carrier Pressure Switch w/ Bracket 0.33 WC for PG8UAA060155ACJA

SKU: CARRIE-PG8UAA060155ACJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier
Guaranteed to fit PG8UAA060155ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket — HK06WC090 for Model PG8UAA060155ACJA

This is the factory OEM replacement pressure switch with mounting bracket (part number HK06WC090) for the Carrier PG8UAA060155ACJA packaged gas furnace. The pressure switch is a critical safety component that monitors negative air pressure created by the draft inducer motor. When the inducer comes up to speed and generates the correct pressure, the switch closes and allows the control board to proceed to ignition. A failed or out-of-spec pressure switch will prevent the furnace from advancing past the inducer stage — resulting in a no-heat lockout, often accompanied by a diagnostic fault code for "pressure switch stuck open" or "inducer fault."

  • Specs: Rated at -0.33 W.C. (inches of water column) | SPST normally-open configuration | Includes factory mounting bracket | Replaces legacy part numbers HK06WC088, HK06WC086, HK06WC076, HK06WC072, HK06WC073, HK06WC074, HK660001, 310315-751, 310315-752, and 326750-751
  • OEM vs Generic: This is a genuine Carrier OEM switch, factory-calibrated to the exact -0.33 W.C. trip point. Off-brand substitutes often carry ±15% tolerance on the set point, leading to nuisance lockouts in cold weather or — worse — failure to detect a degraded inducer, creating a safety hazard.
  • Install difficulty: 2/5 — Before starting, verify the inducer motor and hose connections are functioning correctly, as a failed inducer or cracked hose is a common root cause that resembles a bad switch. Tools needed: flat-blade and Phillips screwdrivers, a U-tube manometer or digital magnehelic gauge (recommended to verify inducer pressure), and needle-nose pliers for hose clamps. Always confirm 24V is removed from the control circuit before disconnecting wiring.
  • Warranty & Shipping: 1-year OEM factory warranty against defects. Ships same business day from our warehouse — order by 3 PM local time for same-day dispatch.

Compatibility: Engineered specifically for the Carrier PG8UAA060155ACJA packaged gas furnace. Also fits multiple PG8UAA and PG8DAA series Carrier models that share the -0.33 W.C. pressure switch specification — verify your unit's data plate and existing switch rating before ordering. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8UAA060155ACJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8UAA060155ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8UAA060155ACJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online