OEM Carrier Pressure Switch with Bracket -0.33 WC for Model PG8UAA048135ABJA — Part# HK06WC090

This is the OEM factory-specified pressure switch with integrated mounting bracket for the Carrier PG8UAA048135ABJA packaged gas furnace. The pressure switch is a normally-open safety device that monitors negative pressure created by the inducer draft motor. Once the inducer reaches proper operating speed and the correct negative pressure is achieved, the switch closes and signals the control board to advance the ignition sequence. When it fails, the furnace will lock out before ignition — often displaying a pressure switch fault code — leaving you with no heat.

  • Specs: -0.33 W.C. (water column) trip point | Includes factory mounting bracket | Single-port, normally open | OEM-matched electrical connector
  • OEM vs Generic: This is a genuine Carrier OEM part (HK06WC090) manufactured to exact factory tolerances. Generic pressure switches often carry wide trip-point variances that can cause nuisance lockouts or, worse, fail to protect against dangerous backdraft conditions.
  • Install difficulty: 2/5 — Power down and confirm zero voltage at the unit before starting. Tools needed: 1/4" nut driver, flat-head screwdriver, and a U-tube manometer or digital manometer if verifying trip point. Photograph the hose and wiring connections before removal. Swap the rubber sensing hose and reconnect the two-wire harness on the new switch.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Directly fits the Carrier PG8UAA048135ABJA packaged gas furnace. This part also supersedes and replaces earlier Carrier pressure switch part numbers including HK06WC088, HK06WC086, HK06WC076, HK06WC073, HK06WC074, HK660001, 310315-751, 310315-752, and 326750-751. Always verify the W.C. rating on your existing switch before ordering. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — no guesswork.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8UAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8UAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8UAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.