Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket .33 WC — HK06WC090 PG8UAA036065
Carrier

OEM Carrier Pressure Switch w/ Bracket .33 WC — HK06WC090 PG8UAA036065

SKU: CARRIE-PG8UAA036065ACJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier
Guaranteed to fit PG8UAA036065 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket .33 WC for Model PG8UAA036065ACJA (HK06WC090)

This is the factory OEM replacement pressure switch with mounting bracket for the Carrier PG8UAA036065ACJA gas furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor during the startup sequence. It must close and confirm adequate draft before the control board advances to the ignition stage. When it fails or gets stuck open, the furnace locks out — often before the burners ever fire — leaving you with a no-heat call and a flashing fault code on the control board.

  • Specs: Rating: –0.33 in. W.C. (water column) | SPST configuration | Includes factory mounting bracket | OEM part number HK06WC090 | Also replaces HK06WC088, HK06WC086, HK06WC076, HK06WC072, HK06WC073, HK06WC074, HK660001, 326750-751, 310315-751, 310315-752
  • OEM vs Generic: OEM pressure switches are calibrated to the exact –0.33 W.C. trip point specified for the PG8UAA036065ACJA. Generic aftermarket switches often carry ±15% tolerance, risking nuisance lockouts in cold weather or, worse, allowing the furnace to fire under unsafe draft conditions.
  • Install difficulty: 2/5 — No special tools required. Turn off power and gas before servicing. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, and a multimeter to confirm switch continuity post-install. Always inspect the hose barb and rubber tubing for cracks before reusing — a split hose mimics a failed switch.
  • Warranty: 1-year OEM manufacturer warranty from date of purchase. In-stock units ship same business day when ordered by 5 PM local time.

Compatibility: Direct OEM fit for the Carrier PG8UAA036065ACJA gas furnace. This part also serves as a superseding replacement for multiple legacy Carrier, Bryant, and Payne pressure switch part numbers — verify the –0.33 W.C. rating on your existing switch label before ordering. Questions about fitment? Our HVAC parts specialists confirm compatibility before every order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — HK06WC090 PG8UAA036065?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — HK06WC090 PG8UAA036065. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — HK06WC090 PG8UAA036065?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online