Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket .33 WC for PG8UAA024065ACJA
Carrier

OEM Carrier Pressure Switch w/ Bracket .33 WC for PG8UAA024065ACJA

SKU: CARRIE-PG8UAA024065ACJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier
Guaranteed to fit PG8UAA024065ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch w/ Bracket .33 WC for Model PG8UAA024065ACJA

This is the genuine OEM replacement pressure switch (part number HK06WC090) factory-specified for the Carrier PG8UAA024065ACJA packaged gas furnace. The pressure switch proves that the draft inducer motor is operating correctly before allowing the ignition sequence to proceed. It does this by detecting negative air pressure (vacuum) generated by the inducer — once the required pressure level is reached, the switch closes and signals the control board to continue startup. When this switch fails, the furnace will typically lock out before ignition, display a pressure-switch fault code, or cycle the inducer continuously without ever lighting the burner.

  • Specs: Rated .33 W.C. (inches of water column) | Includes factory mounting bracket | Single-port diaphragm-style switch | 24V control circuit compatible
  • OEM vs Generic: This is a genuine Carrier OEM part, manufactured to exact factory tolerances. Generic aftermarket switches often carry a ±15–20% W.C. variance that can cause nuisance lockouts, failed ignition attempts, or — worse — unsafe operation. OEM is the only reliable choice for a safety-critical component like this.
  • Install difficulty: 2/5 — Before starting, power down the furnace at the disconnect and thermostat. Tools needed: flathead and Phillips screwdriver, needle-nose pliers, and a manometer or magnehelic gauge if you want to verify pressure after install. Disconnect the rubber vacuum hose and two wiring terminals, unmount the bracket, and reverse the process with the new switch. Always confirm the hose is free of cracks, kinks, or moisture before buttoning up.
  • Warranty: 1-year OEM manufacturer warranty. In-stock and ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PG8UAA024065ACJA packaged gas furnace. This part also supersedes and replaces earlier part numbers including HK06WC088, HK06WC086, HK06WC076, HK06WC072, HK06WC073, HK06WC074, 326750-751, HK660001, 310315-751, and 310315-752. Always verify the W.C. rating on your existing switch and the part number on your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — reach out before you order if you have any doubt.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8UAA024065ACJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8UAA024065ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8UAA024065ACJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.