OEM Carrier Flame Sensor with Wire LH680014 for Model PG8UAA024045ABJA

This is the factory OEM replacement flame sensor with wire harness for the Carrier PG8UAA024045ABJA packaged gas unit. The flame sensor — also called a flame rod — is a safety device that detects the presence of a burner flame by passing a small DC current through the flame itself. When the sensor becomes coated with oxidation or carbon buildup, its ability to conduct that signal degrades, causing the control board to cut the gas valve within 5–8 seconds of ignition as a safety precaution. The result: the furnace lights briefly, then shuts off and goes into lockout — often mistaken for a failed igniter or gas valve. Replacing this OEM sensor restores proper flame signal strength and reliable heat.

  • Specs: Factory OEM flame rod with pre-attached wire harness | Exact mounting bracket angle and rod length matched to Carrier PG8UAA024045ABJA burner assembly | Part Number: LH680014
  • OEM vs Generic: OEM sensors feature the correct rod alloy composition and wire gauge specified by Carrier engineering. Generic sensors may have incorrect rod geometry or thinner wire insulation, risking intermittent flame signal or premature failure in high-temperature environments.
  • Install Difficulty: 2/5 — Shut off gas and disconnect power before servicing. Tools needed: 1/4" nut driver or flat-head screwdriver (bracket screw), needle-nose pliers. Disconnect the wire lead, remove the single mounting screw, slide out the old sensor, reverse to install. Clean the burner surface at the rod tip if carbon buildup is present. No soldering required — wire harness is included.
  • Warranty: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed as the direct OEM replacement for Carrier model PG8UAA024045ABJA. Always verify your unit's existing part number on the sensor body or wiring diagram before ordering to confirm fitment. Our team is available to verify compatibility before you buy — ships same business day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PG8UAA024045ABJA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PG8UAA024045ABJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PG8UAA024045ABJA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.