Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier LP Gas Pressure Switch HK02LB008 for PG8MEA024045ACJA
Carrier

OEM Carrier LP Gas Pressure Switch HK02LB008 for PG8MEA024045ACJA

SKU: CARRIE-PG8MEA024045ACJA-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit PG8MEA024045ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch HK02LB008 / HK06WC091 for Model PG8MEA024045ACJA

This is the factory OEM LP gas pressure switch for the Carrier PG8MEA024045ACJA packaged gas/electric unit. The pressure switch is a critical safety device that monitors the negative pressure (vacuum) created by the draft inducer motor before allowing ignition to proceed. If the inducer fails to generate sufficient vacuum — or if the switch itself fails — the furnace control board will lock out the ignition sequence entirely, resulting in a no-heat call. A failed pressure switch typically causes the system to attempt ignition and immediately abort, with a diagnostic fault code indicating a pressure switch fault or open pressure switch condition.

  • OEM Part Numbers: HK02LB008 (LP Gas Pressure Switch) | HK06WC091 (Pressure Switch High Fire) — both covered by this listing for the PG8MEA024045ACJA
  • Specs: Cut-out pressure set at 6.5" W.C. | SPST configuration | Suitable for LP/propane gas applications | Mounts horizontally or vertically | Factory-matched to Carrier/Bryant/Payne furnace and packaged unit platforms
  • OEM vs Generic: OEM pressure switches are calibrated to exact W.C. setpoints at the factory. Off-brand switches frequently drift outside specification, causing nuisance lockouts or, worse, failing to trip during an actual inducer fault — a safety risk. Always replace with OEM on gas appliances.
  • Install Difficulty: 2/5 — Shut off gas and power before servicing. Locate the switch on the inducer housing, disconnect the two wiring terminals and vacuum hose, and swap in the new switch. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter (to verify continuity pre-install). Total job typically under 20 minutes for a qualified technician.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG8MEA024045ACJA packaged gas/electric unit. Also fits select Bryant and Payne models sharing the same inducer and pressure switch platform. Always verify the W.C. rating and part number stamped on your existing switch before ordering. Our parts team is available to confirm fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8MEA024045ACJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8MEA024045ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8MEA024045ACJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.