OEM Carrier LP Gas Pressure Switch 6.5 WC for PG8MAA060090AGJA
Carrier

OEM Carrier LP Gas Pressure Switch 6.5 WC for PG8MAA060090AGJA

SKU: CARRIE-PG8MAA060090AGJA-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit PG8MAA060090AGJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch (HK02LB008) for Model PG8MAA060090AGJA

This OEM gas pressure switch is the factory-specified replacement for the Carrier PG8MAA060090AGJA packaged gas unit. The pressure switch monitors gas supply pressure and opens or closes the electrical circuit when the set-point threshold is reached, protecting the heat exchanger and preventing unsafe operation. When this switch fails, the furnace will typically enter a no-heat lockout immediately after ignition is attempted, or will refuse to fire at all — a classic symptom technicians trace back to a faulty pressure proving circuit.

  • Specs: Cut-out pressure 6.5 in w.c. | LP (propane) gas rated | Mounts horizontally or vertically | OEM part numbers: HK02LB008, HK06WC091, HK06WC100 (w/ bracket)
  • OEM vs Generic: This is a genuine Carrier OEM part, factory-calibrated to the exact 6.5 in w.c. set-point. Generic pressure switches frequently drift out of tolerance, causing nuisance lockouts or — worse — allowing unsafe low-pressure operation.
  • Install difficulty: 2/5 — Shut off gas supply and power before servicing. Tools needed: 1/4" nut driver, small flat-head screwdriver, and a manometer to verify downstream pressure after replacement. Photograph all wiring and tubing connections before disconnecting.
  • Warranty & Shipping: 1-year OEM manufacturer warranty. Orders placed by 3 PM local time ship same business day from our warehouse.

Compatibility: Designed for the Carrier PG8MAA060090AGJA packaged gas unit. Cross-references HK06WC091 (standard) and HK06WC100 (with mounting bracket). Note: HK02LB008 has been superseded — we stock the current OEM equivalent. Verify your unit's gas type (LP vs. natural gas) and confirm the pressure rating on your data plate before ordering. Our fitment team is available to verify compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8MAA060090AGJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8MAA060090AGJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8MAA060090AGJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.