Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch Assembly w/Bracket HK06WC069 — PG8MAA04811
Carrier

OEM Carrier Pressure Switch Assembly w/Bracket HK06WC069 — PG8MAA04811

SKU: CARRIE-PG8MAA048110ADJA-PRESSURE_SWITCH-HK06WC069 Brand: Carrier
Guaranteed to fit PG8MAA04811 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch Assembly with Bracket HK06WC069 for Model PG8MAA048110ADJA

This is the genuine OEM Carrier Pressure Switch Assembly with Bracket (part number HK06WC069), factory-specified for the Carrier PG8MAA048110ADJA gas furnace. The pressure switch is a critical safety device that monitors negative pressure (draft) created by the inducer blower motor. Before every ignition cycle, the control board checks this switch to confirm the inducer is operating and the flue is clear. When the switch fails — or the hose, port, or inducer driving it fails — the board locks out the furnace before the gas valve ever opens, leaving you with a no-heat call and often a fault code pointing directly to draft pressure.

  • Specs: Single-stage draft pressure switch | Includes factory mounting bracket | .27" W.C. break / .42" W.C. max make | Honeywell-manufactured internals (IS20205-4021) | OEM-matched setpoint — no field calibration required
  • OEM vs Generic: This factory OEM part is pre-set to the exact W.C. rating engineered for the PG8MAA048110ADJA. Aftermarket substitutes are often rated at wider tolerances, risking nuisance lockouts or, worse, failing to detect a true flue blockage.
  • Install difficulty: 2/5 — Power down and disconnect gas before starting. Tools needed: 1/4" nut driver, needle-nose pliers, and a short length of replacement hose if the existing tubing is cracked. Always inspect the rubber hose and inducer port for blockage before condemning the switch itself — a clogged port is the #1 misdiagnosis.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Directly replaces OEM part HK06WC069 on the Carrier PG8MAA048110ADJA gas furnace. Also fits select Bryant and Payne models sharing this pressure switch specification — verify your model's data plate W.C. rating before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch Assembly w/Bracket HK06WC069 — PG8MAA04811?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch Assembly w/Bracket HK06WC069 — PG8MAA04811. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch Assembly w/Bracket HK06WC069 — PG8MAA04811?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online