Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Board HK42FZ013 for PG8MAA048110ACJA
Carrier

OEM Carrier Furnace Control Board HK42FZ013 for PG8MAA048110ACJA

SKU: CARRIE-PG8MAA048110ACJA-CONTROL_BOARD-HK42FZ013 Brand: Carrier
Guaranteed to fit PG8MAA048110ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Integrated Control Board HK42FZ013 for Model PG8MAA048110ACJA

This OEM Carrier integrated furnace control (IFC) board, part number HK42FZ013, is the factory-specified replacement for the Carrier PG8MAA048110ACJA gas furnace. The control board is the brain of your furnace — it sequences every operating stage including draft inducer startup, hot surface ignition, gas valve operation, blower motor timing, and safety lockout logic. When this board fails, symptoms typically include a furnace that won't ignite, a system stuck in lockout, erratic blower behavior, or a unit that powers on but produces no heat. A faulty board may also trigger continuous fault codes with no apparent mechanical cause.

  • Specs: Input range 98–132 VAC at 60 Hz | Ignitor output: 5A at 120 VAC | Cool blower: 30A, 2 HP, 240 VAC | Heat blower: 5A, 1/2 HP, 240 VAC | Inducer motor: 4A FLA / 8.0 LRA at 120 VAC | Microprocessor-based design with onboard diagnostic LED fault codes | OEM board reference: CEPL130438-01 / CEBD430438
  • OEM vs Generic: This is the genuine OEM Carrier control board — factory-programmed with exact sequencing logic, timing delays, and safety thresholds for the PG8MAA048110ACJA. Generic aftermarket boards may lack precise timing calibration, increasing risk of nuisance lockouts, premature component wear, or voided equipment warranties.
  • Install Difficulty: 3/5 — Intermediate skill level recommended. Shut off power and gas before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, smartphone or camera to photograph all wiring harness connections prior to removal. Transfer wiring connectors one at a time to avoid miswiring. Verify all safeties and perform a full heat cycle test after installation.
  • Warranty: 1-year OEM factory warranty against manufacturing defects. Ships same business day from our stocked warehouse — no backorder delays.

Compatibility: Designed for the Carrier PG8MAA048110ACJA gas furnace. Also cross-references OEM part numbers HK42FZ034 (successor part), CEPL130438-01, and CEBD430438. Always verify your existing board's part number against your unit's data plate before ordering. Need help confirming fitment? Our HVAC parts specialists are standing by to verify compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG8MAA048110ACJA?
Yes. This is the factory-specified OEM control board for the Carrier PG8MAA048110ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG8MAA048110ACJA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.