Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Silicon Nitride Hot Surface Igniter for PG8JEA024045ACJA
Carrier

OEM Carrier Silicon Nitride Hot Surface Igniter for PG8JEA024045ACJA

SKU: CARRIE-PG8JEA024045ACJA-IGNITER-LH33ZG001 Brand: Carrier
Guaranteed to fit PG8JEA024045ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Silicon Nitride Hot Surface Igniter for PG8JEA024045ACJA

The hot surface igniter is what lights the burners in your Carrier PG8JEA024045ACJA on every heat cycle. The control board feeds the igniter voltage, it heats to a glowing white, and the opening gas valve ignites across the hot element. When the igniter is worn or cracked, the furnace produces no heat: the inducer runs, the system purges, but the burners never light and the board locks out after a few failed attempts. Telltale signs include cold air from the registers, repeated short-cycling, and a clicking gas valve with no flame. Igniters are the most-replaced wear item on these packaged gas furnaces. This OEM replacement uses a silicon nitride element with a nominal cold resistance around 40–75 ohms. Silicon nitride is dramatically tougher than legacy silicon carbide — it shrugs off the thermal shock and vibration that crack older igniters — so it lasts longer in the demanding duty cycle of a packaged unit. With igniters, OEM specification is everything. Too much resistance and the element never glows hot enough to light gas reliably, triggering nuisance lockouts; too little and it overdraws current, burning itself and the board's driver circuit out early. Generic igniters routinely use looser resistance tolerances and cheaper ceramic that degrade quickly. The OEM part is dialed to Carrier's exact voltage and ignition timing. Install difficulty: 2 of 5. Tools: 1/4" nut driver for the mounting screw and a multimeter to check resistance before and after. SAFETY: shut off the gas and kill power at the breaker first, and only handle the igniter by its ceramic base — skin oils left on the element create hot spots that crack it. Ships same business day from our stocked warehouse on orders before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PG8JEA024045ACJA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Carrier PG8JEA024045ACJA?
Yes. This is the factory-specified OEM igniter for the Carrier PG8JEA024045ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Carrier PG8JEA024045ACJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online