OEM Carrier LP Gas Pressure Switch for Model PG8JAA036070AGJA

This is the factory OEM replacement LP gas pressure switch for the Carrier PG8JAA036070AGJA packaged gas unit. The pressure switch is a critical safety and sequencing component — it monitors the pressure differential produced by the inducer (draft) motor and proves the combustion airflow path is clear before allowing the gas valve to open. When this switch fails or sticks, the furnace will attempt a call for heat, run the inducer, and then lock out without ever reaching the ignition stage. Fault codes for a failed pressure switch typically appear as a 3-flash or pressure switch open/stuck sequence on the control board LED.

  • OEM Part Numbers: Primary — HK02LB008 (Gas Pressure Switch) | Related — HK06WC091 (Pressure Switch) | HK06WC100 (Pressure Switch w/ Bracket). Verify your specific variant against your unit's wiring diagram before ordering.
  • Specs: LP (propane) gas pressure switch | Cut-out pressure: 6.5" W.C. (inches water column) | Factory-matched pressure rating | SPST normally-open configuration | OEM cross-reference: GFS3451-4036
  • OEM vs Generic: This is a genuine Carrier factory-authorized part, manufactured to exact pressure tolerances. Aftermarket switches often carry ±10–15% pressure variance, which can cause nuisance lockouts or — worse — unsafe ignition sequences. Don't compromise on safety-critical components.
  • Install Difficulty: 2/5 — Shut off gas supply and 120V power before starting. Tools needed: 1/4" nut driver, flathead screwdriver, manometer (recommended to verify W.C. after install). Disconnect the two wire leads and one rubber hose, swap the switch, and reconnect. Always confirm the inducer motor is functioning correctly before condemning the switch alone.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered as a direct OEM replacement for the Carrier PG8JAA036070AGJA packaged gas heating unit. Also fits select Bryant and Payne models sharing this pressure switch specification — confirm part number match on your unit's data plate or wiring schematic. Have a fitment question? Our HVAC parts specialists verify compatibility before you order. Order now — in stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8JAA036070AGJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8JAA036070AGJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8JAA036070AGJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.