Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier LP Gas Pressure Switch 6.5
Carrier

OEM Carrier LP Gas Pressure Switch 6.5" W.C. for PG8JAA036070AFJA

SKU: CARRIE-PG8JAA036070AFJA-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit PG8JAA036070AFJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch for Model PG8JAA036070AFJA

This is the factory OEM LP (propane) gas pressure switch for the Carrier PG8JAA036070AFJA packaged gas unit. The pressure switch monitors the negative pressure produced by the inducer motor to confirm safe combustion airflow before allowing the gas valve to open. When this switch fails or sticks open, the furnace will lock out on the first call for heat — often with no error code or with a pressure switch fault code — leaving you without heat until the root cause is resolved.

  • Specs: LP (propane) gas pressure switch | 6.5" W.C. cut-out set point | SPST normally-open configuration | Replaces OEM part numbers HK02LB008, HK06WC091, and HK06WC100 (bracket version)
  • OEM vs Generic: OEM switches are factory-calibrated to the exact W.C. rating for your unit. Off-spec generic switches can trip too early or too late, causing nuisance lockouts or unsafe operation. Always verify the W.C. rating matches your unit's data plate.
  • Install difficulty: 2/5 — Shut off power and gas before beginning. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, and a manometer (recommended to verify set point post-install). Note: HK06WC100 variant includes a mounting bracket — confirm your installation needs before ordering.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility Note: Designed for the Carrier PG8JAA036070AFJA packaged gas/electric unit. This switch is specific to LP (propane) fuel configurations — do not substitute for natural gas pressure switch variants. Cross-references: HK02LB008 (Gas Pressure Switch), HK06WC091 (Pressure Switch), HK06WC100 (Pressure Switch w/ Bracket). Order with confidence — our team verifies fitment before your order ships.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8JAA036070AFJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8JAA036070AFJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8JAA036070AFJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online