Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier LP Gas Pressure Switch 6.5
Carrier

OEM Carrier LP Gas Pressure Switch 6.5" WC — PG8JAA024070AEJA

SKU: CARRIE-PG8JAA024070AEJA-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit PG8JAA024070AEJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch HK02LB008 / HK06WC091 for Model PG8JAA024070AEJA

This OEM LP gas pressure switch is the factory-specified replacement for the Carrier PG8JAA024070AEJA packaged gas unit. The pressure switch monitors gas supply pressure and opens or closes the electrical circuit when the setpoint is reached, acting as a critical safety device that prevents the furnace from operating outside safe pressure parameters. When this switch fails, the unit will typically enter a lockout condition — refusing to fire or shutting down immediately after ignition attempt — leaving you with no heat until the fault is resolved.

  • Specs: LP (Propane) Gas Pressure Switch | 6.5" WC cut-out setpoint | SPST configuration | Replaces OEM part numbers HK02LB008 & HK06WC091 | Compatible with air, natural gas, and LP gas applications | Mountable in horizontal or vertical position
  • OEM vs Generic: This is a genuine Carrier OEM pressure switch, factory-calibrated to the exact 6.5" WC setpoint required by your unit. Generic aftermarket switches often ship with loose tolerances that can cause nuisance lockouts or — worse — allow unsafe operating conditions to go undetected.
  • Install difficulty: 2/5 — Shut off gas and electrical supply before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a manometer to verify pressure after installation. Photograph all hose and wiring connections before disconnecting. Note: always confirm gas type (LP vs. natural gas) matches the switch specification.
  • Warranty & Shipping: 1-year OEM factory warranty against defects. In stock and ships same business day from our warehouse. Note: HK02LB008 has been superseded — HK02MB008 is the current direct OEM replacement; confirm your unit's part requirement before ordering.

Compatibility: Engineered for the Carrier PG8JAA024070AEJA packaged gas unit. Also fits select Bryant and Payne models using the HK02LB008 or HK06WC091 pressure switch specification — verify your model's data plate and gas type before ordering. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier LP Gas Pressure Switch 6.5" WC — PG8JAA024070AEJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier LP Gas Pressure Switch 6.5" WC — PG8JAA024070AEJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier LP Gas Pressure Switch 6.5" WC — PG8JAA024070AEJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online