Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch Assembly w/Bracket — HK06WC069
Carrier

OEM Carrier Pressure Switch Assembly w/Bracket — HK06WC069

SKU: CARRIE-PG8JAA024070ABJA-PRESSURE_SWITCH-HK06WC069 Brand: Carrier
Guaranteed to fit HK06WC069 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch Assembly with Bracket for Model PG8JAA024070ABJA — Part# HK06WC069

This is the genuine OEM Carrier Pressure Switch Assembly with Bracket (Part# HK06WC069), the factory-specified replacement for the Carrier PG8JAA024070ABJA gas furnace. The pressure switch is a critical safety component that monitors negative pressure created by the draft inducer motor. Once the inducer proves adequate airflow, the switch closes and allows the ignition sequence to proceed. When the pressure switch fails or sticks open, the furnace will lock out before ignition — leaving you with a no-heat call and a blinking fault code on the control board.

  • Specs: Single-stage pressure switch | Set point: -0.27" W.C. (break) / -0.42" W.C. max make | Includes factory bracket assembly | Direct OEM replacement — no modifications required
  • OEM vs Generic: This is a genuine Carrier OEM part, manufactured to exact factory pressure tolerances. Aftermarket switches often carry wider tolerance ranges, which can cause nuisance lockouts or — worse — fail to shut down on a true inducer failure, creating a safety hazard.
  • Install difficulty: 2/5 — Power down and disconnect the furnace before starting. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers. Disconnect the rubber hose and two wires, swap the bracket-mounted switch, and reconnect. Always clear any blockage in the hose port before installing the new switch.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse when ordered before cut-off.

Compatibility: Engineered specifically for the Carrier PG8JAA024070ABJA packaged gas furnace. This part is also cross-referenced to Bryant and Payne models sharing the same inducer and pressure switch configuration — verify your model's data plate and existing switch set point before ordering. Our fitment team is available to confirm compatibility before you buy. Order now and receive fast, same-day shipping straight to your door.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch Assembly w/Bracket — HK06WC069?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch Assembly w/Bracket — HK06WC069. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch Assembly w/Bracket — HK06WC069?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online