OEM Carrier Pressure Switch w/ Bracket HK06WC090 for Model PG8DAA060135ADJA

This is the genuine OEM pressure switch with mounting bracket for the Carrier PG8DAA060135ADJA gas furnace. The pressure switch is a critical safety component that proves the inducer blower is creating adequate negative pressure before allowing the ignition sequence to proceed. When it fails or sticks open, the control board detects a fault and locks out the furnace — leaving you with no heat. Common symptoms include the inducer motor running but the furnace never advancing past the proving stage, a flashing fault code indicating a pressure switch error, or the furnace cycling the inducer repeatedly without lighting.

  • Specs: –0.33" W.C. (inches water column) rated | Includes factory mounting bracket | SPST normally-open configuration | Direct OEM replacement for Carrier part HK06WC090
  • OEM vs Generic: This OEM switch is factory-calibrated to the exact trip point required by your PG8DAA060135ADJA control board. Off-brand switches often carry wide W.C. tolerances that can cause nuisance lockouts or, worse, fail to detect a true inducer fault — a potential safety risk.
  • Install difficulty: 2/5 — Power down and disconnect gas before servicing. Tools needed: 1/4" nut driver, needle-nose pliers, and a short length of replacement tubing (if original hose is cracked). Photograph existing hose routing and wire connections before removal. Snap bracket into original mounting location and reconnect hose and wires.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PG8DAA060135ADJA packaged gas furnace. Also replaces legacy part numbers 326750-751, HK06WC088, HK06WC086, HK660001, 310315-751, 310315-752, HK06WC076, HK06WC072, HK06WC073, and HK06WC074. Always verify the W.C. rating printed on your existing switch before ordering. Order today and our team will confirm fitment before your part ships.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket HK06WC090 — PG8DAA060135ADJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket HK06WC090 — PG8DAA060135ADJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket HK06WC090 — PG8DAA060135ADJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.