The Carrier HK06WC090 is the factory OEM pressure switch with mounting bracket for the PG8DAA060115ABJA packaged gas furnace. The pressure switch is a critical safety device that monitors negative pressure produced by the inducer (draft) motor before allowing ignition to proceed. When the inducer creates the correct draft, the diaphragm inside the switch closes the circuit and signals the control board to advance to the ignition sequence. If the switch fails — or if it senses insufficient draft — the furnace will lock out on a pressure switch fault, typically displaying a fault code and delivering no heat.
Compatibility: Engineered as the direct OEM replacement for Carrier model PG8DAA060115ABJA. Also supersedes earlier Carrier part numbers including HK06WC088, HK06WC086, HK06WC076, HK06WC072, HK06WC073, HK06WC074, HK660001, 326750-751, 310315-751, and 310315-752. Verify the W.C. rating on your existing switch before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — no guesswork.