OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —
Carrier

OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —

SKU: CARRIE-PG8DAA036095ADJA-CONTROL_BOARD-HK42FZ016 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 for Model PG8DAA036095ADJA

This is the factory OEM Integrated Furnace Control (IFC) board for the Carrier PG8DAA036095ADJA gas furnace, sold under primary OEM part number HK42FZ016 and its current successor kit 325878-751. The IFC board is the brain of your furnace — it sequences every heating cycle from inducer startup through ignition, gas valve control, blower operation, and safe shutdown. When it fails, symptoms include a complete no-heat lockout, furnace starting then immediately shutting down, erratic blower behavior, or a fault LED flashing a diagnostic code with no recovery.

  • Specs: Input Voltage: 98–132 VAC at 60 Hz | Ignitor Output: 5A at 120 VAC | Cool Blower: 30A, 2 HP, 240 VAC | Heat Blower: 5A, 1/2 HP, 240 VAC | Inducer Motor: 4A, FLA-8.0 LRA at 120 VAC | Compatible with 24 VAC standard thermostats | Diagnostic LED fault codes included
  • OEM vs Generic: This is a genuine Carrier OEM board — not a third-party ICM282 clone. OEM firmware is factory-calibrated to the exact ignition timing, blower delay profiles, and lockout thresholds of the PG8DAA036095ADJA. Aftermarket boards often use generalized firmware that can cause nuisance lockouts or premature component wear.
  • Install Difficulty: 3/5 — Shut off gas and 120V power before starting. Photograph all wiring harness connections before disconnecting. The 325878-751 kit includes adapter plug harnesses for compatibility with older board generations. Tools needed: 1/4" nut driver, needle-nose pliers, smartphone camera. Always verify fault LED label is affixed to furnace door after install. Estimated time: 30–60 minutes.
  • Warranty: 1-year OEM manufacturer warranty against defects. Ships same business day from our warehouse in OEM-protective packaging.

Compatibility: Designed for Carrier model PG8DAA036095ADJA single-stage gas furnace. OEM part HK42FZ016 has been superseded by kit 325878-751, which ships with adapter harnesses for seamless installation. Cross-references: CEBD431012-01A, CEPL1311012-01, 1012-940-M. Verify your existing board part number on the board label before ordering. Have a question about fitment? Our HVAC technicians verify compatibility before you buy — contact us today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.