Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket -0.33
Carrier

OEM Carrier Pressure Switch w/ Bracket -0.33" WC for PG8DAA036070ABJA

SKU: CARRIE-PG8DAA036070ABJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier
Guaranteed to fit PG8DAA036070ABJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch -0.33" WC with Bracket (HK06WC090) for Model PG8DAA036070ABJA

This is the genuine OEM factory-replacement pressure switch for the Carrier PG8DAA036070ABJA gas furnace. The pressure switch is a critical safety device that monitors the negative pressure (draft) created by the inducer motor. Once the inducer reaches proper speed, the switch closes and signals the control board to proceed to ignition. When this switch fails, the furnace locks out before the igniter ever fires — leaving you with no heat and typically a fault code indicating a pressure switch fault or open pressure switch condition.

  • Specs: -0.33" W.C. (water column) set point | SPST (Single-Pole Single-Throw) configuration | Includes factory mounting bracket | OEM Part Number: HK06WC090
  • OEM vs Generic: OEM pressure switches are calibrated to exact W.C. tolerances at the factory. Generic aftermarket switches frequently drift from their rated set point, causing nuisance lockouts or — more dangerously — failing to detect a blocked flue. Always choose OEM for a safety-critical component.
  • Install difficulty: 2/5 — Power down the furnace and lock out the disconnect before beginning. Tools needed: 1/4" nut driver, needle-nose pliers, and a short length of 5/16" ID hose if the existing hose is cracked. Photograph the hose routing and wiring terminals before disconnecting. Bracket hardware is included.
  • Warranty: 1-year OEM manufacturer warranty. In-stock orders ship same business day when placed by 5 PM local time.

Compatibility: Direct OEM replacement for Carrier PG8DAA036070ABJA gas furnaces. Also replaces legacy part numbers HK06WC088, HK06WC086, HK06WC076, HK06WC074, HK06WC073, HK06WC072, HK660001, 310315-751, 310315-752, and 326750-751. Verify the W.C. rating on your existing switch label before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — no guesswork.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PG8DAA036070ABJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PG8DAA036070ABJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PG8DAA036070ABJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.