Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Furnace Control Circuit Board for PG8DAA036070AAJA
Carrier

OEM Carrier Furnace Control Circuit Board for PG8DAA036070AAJA

SKU: CARRIE-PG8DAA036070AAJA-CONTROL_BOARD-HK42FZ016 Brand: Carrier
Guaranteed to fit PG8DAA036070AAJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Furnace Control Circuit Board for PG8DAA036070AAJA

The integrated furnace control board is the brain of your Carrier PG8DAA036070AAJA packaged gas/electric unit. It sequences every ignition cycle — energizing the inducer, proving the pressure switch, powering the hot surface igniter, opening the gas valve, monitoring the flame sensor, and timing the blower on/off delays. When the board fails, symptoms range widely: no response on a heat call, a blower that runs constantly or not at all, burners that won't light despite a good igniter, or a diagnostic LED flashing a fault code through the inspection window. Burned relay contacts and cracked solder joints around the gas-valve and blower relays are the most common failure points. This OEM control board carries the correct relay complement for the PG8 platform — inducer, igniter, gas-valve, and line-voltage blower relays — plus the low-voltage terminal strip and onboard diagnostics. It is matched to the unit's ignition timing: trial-for-ignition period, inter-purge, and blower-off delay. Carrier revised these boards across production runs, so always confirm the manufacturer part number printed on your existing board against the data plate before ordering. Why OEM matters: a generic 'universal' board may fit the footprint but run different timings, causing delayed ignition, short blower cycles, or no-heat faults. OEM boards use properly rated relay contacts; undersized aftermarket relays pit and weld faster under the inductive load of the blower motor, leading to repeat failures and callbacks. Install difficulty: 3/5. Tools: 1/4" nut driver, a phone camera to photograph the wiring before disconnecting, multimeter. SAFETY: kill the breaker and the unit disconnect before touching the board — line voltage (120/240V) is present at the relays even when the thermostat is off. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PG8DAA036070AAJA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG8DAA036070AAJA?
Yes. This is the factory-specified OEM control board for the Carrier PG8DAA036070AAJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG8DAA036070AAJA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.