OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —
Carrier

OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —

SKU: CARRIE-PG8DAA024070ADJA-CONTROL_BOARD-HK42FZ016 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 for Model PG8DAA024070ADJA

This OEM integrated furnace control board (IFC) is the factory-specified replacement for the Carrier PG8DAA024070ADJA gas furnace. Originally supplied as HK42FZ016 and superseded by the updated kit 325878-751, this microprocessor-based board orchestrates every critical function of your furnace — from inducer startup and hot surface ignition sequencing to blower motor timing, gas valve control, and fault-code diagnostics. When it fails, symptoms include a complete no-heat lockout, furnace starting and immediately shutting down, erratic blower behavior, or a solid/flashing LED fault code with no call-for-heat response.

  • Specs: Input range 98–132 VAC at 60 Hz | Ignitor output: 5A at 120 VAC | Cool blower: 30A / 2 HP / 240 VAC | Heat blower: 5A / 1/2 HP / 240 VAC | Inducer motor: 4A (FLA), 8.0A (LRA) at 120 VAC | Compatible with 24 VAC standard thermostat
  • OEM vs Generic: The OEM 325878-751 kit ships with factory adapter harnesses for plug-and-play installation, eliminating splicing. Generic boards omit these harnesses, lack factory-calibrated timing sequences, and can introduce nuisance lockouts or unsafe ignition delays.
  • Install difficulty: 3/5 — Shut off gas supply and 120V power at the disconnect before starting. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone/camera to photograph all wiring before disconnecting. Static discharge caution required — handle board by edges only. Typical install time: 45–75 minutes.
  • Warranty: 1-year OEM factory warranty on new board. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered for Carrier PG8DAA024070ADJA single-stage gas furnaces. Part number 325878-751 is the current OEM successor to HK42FZ016 and includes adapter plug harnesses for legacy wiring configurations. Verify your existing board's part number on the label before ordering — fits fixed-speed Carrier, Bryant, and Payne furnace platforms sharing the HK42FZ series IFC. Questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — same-day shipping available.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Integrated Furnace Control Board HK42FZ016 / 325878-751 —?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.