OEM Carrier Integrated Furnace Control Board HK42FZ016 for PG8DAA02405
Carrier

OEM Carrier Integrated Furnace Control Board HK42FZ016 for PG8DAA02405

SKU: CARRIE-PG8DAA024050ADJA-CONTROL_BOARD-HK42FZ016 Brand: Carrier
Guaranteed to fit PG8DAA02405 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Integrated Furnace Control Board HK42FZ016 for Model PG8DAA024050ADJA

This is the OEM Carrier Integrated Furnace Control Board (IFC), part number HK42FZ016 (superseded/kit version: 325878-751), factory-specified for the Carrier PG8DAA024050ADJA gas furnace. The IFC board is the brain of your furnace — it sequences ignition, controls the inducer motor, regulates blower timing, monitors the flame sensor, manages the gas valve, and orchestrates all safety shutdowns. When it fails, you may experience a complete no-heat condition, repeated ignition lockouts, erratic blower operation, a furnace that starts and immediately shuts down, or a unit that shows fault codes but never fires. Diagnosing a failed control board should always come after ruling out the igniter, flame sensor, and pressure switch, as those components fail more frequently and are less expensive to replace.

  • OEM Part Numbers: HK42FZ016 (original) | 325878-751 (current OEM kit with wiring harness adapters) | Cross-reference: CEPL130438-01, CEBD430438-09A, 1012-940-M
  • Specifications: Input: 98–132 VAC at 60 Hz | Ignitor Output: 5A at 120 VAC | Cool Blower: 30A, 2 HP, 240 VAC | Heat Blower: 5A, 1/2 HP, 240 VAC | Inducer Motor: 4A FLA / 8.0 LRA at 120 VAC | Gas Valve: 24 VAC standard | Diagnostic LED fault codes included | Microprocessor-based with 100% gas shutoff on ignition failure | Reverse polarity and brownout protection
  • OEM vs Generic: OEM boards are programmed with Carrier-specific ignition timing, blower delay sequences, and safety lockout logic. Aftermarket boards often use generic firmware that can cause nuisance lockouts, improper blower off-delays, and voided equipment warranties. Always use OEM for furnaces still under manufacturer warranty.
  • Install Difficulty: 3/5 — Power down the furnace and confirm zero voltage before handling the board. Photograph all wire harness connections before unplugging. The 325878-751 kit includes wiring adapter harnesses for older-style boards. Tools needed: flathead and Phillips screwdrivers, nut driver, multimeter, camera or phone for documentation. Recommend ESD precautions when handling the board.
  • Warranty: 1-year OEM factory warranty against manufacturing defects. Ships same business day from our warehouse.

Compatibility: Factory-specified for Carrier model PG8DAA024050ADJA single-stage gas furnace. Also compatible across the broader Carrier, Bryant, and Payne fixed-speed furnace platform — see compatibility note below. Verify your existing board's part number on the label before ordering. Questions about fitment? Our HVAC-certified team confirms part compatibility before you buy. Order by 3 PM local time — ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PG8DAA02405?
Yes. This is the factory-specified OEM control board for the Carrier PG8DAA02405. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PG8DAA02405?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.