Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket .33 WC — PG8DAA024050ACJA
Carrier

OEM Carrier Pressure Switch w/ Bracket .33 WC — PG8DAA024050ACJA

SKU: CARRIE-PG8DAA024050ACJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier
Guaranteed to fit PG8DAA024050ACJA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket .33" W.C. for Model PG8DAA024050ACJA

This is the factory OEM replacement pressure switch with mounting bracket for the Carrier PG8DAA024050ACJA packaged gas furnace. The pressure switch is a critical safety device that monitors negative pressure created by the inducer motor before allowing the ignition sequence to proceed. When it fails or sticks open, your furnace will lock out before ignition — leaving you without heat. Common symptoms include a blinking fault code indicating a pressure switch fault, the inducer running but the furnace never advancing to ignition, or the system continuously recycling through the startup sequence without firing.

  • Specs: .33" W.C. (water column) rating | Includes mounting bracket | Direct OEM replacement | Replaces superseded part numbers HK06WC086, HK06WC088, HK06WC072, HK06WC073, HK06WC074, HK06WC076
  • OEM vs Generic: This is a genuine Carrier OEM part calibrated to the exact .33" W.C. trip point for the PG8DAA series. Generic aftermarket switches often carry looser pressure tolerances, which can result in nuisance lockouts or — worse — unsafe ignition attempts.
  • Install difficulty: 2/5 — Power off the furnace at the disconnect before beginning. Tools needed: flathead screwdriver, needle-nose pliers, and a phone or camera to photograph hose and wiring connections before removal. Inspect the rubber pressure hose for cracks while the switch is out — a cracked hose is a common companion failure.
  • Warranty: 1-year OEM manufacturer warranty from date of purchase. Orders placed by 5 PM EST ship same business day from our warehouse.

Compatibility: Engineered for the Carrier PG8DAA024050ACJA packaged gas furnace unit. This part also cross-references to legacy Carrier, Bryant, and Payne units previously serviced with HK06WC086 or HK06WC088. Always verify the .33" W.C. rating on your unit's existing switch or service manual before ordering. Have a fitment question? Our HVAC parts specialists are available to confirm compatibility before you buy — order with confidence and get your heat back fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — PG8DAA024050ACJA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — PG8DAA024050ACJA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Pressure Switch w/ Bracket .33 WC — PG8DAA024050ACJA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.