Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA042000AAAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA042000AAAA

SKU: CARRIE-PF4MNA042000AAAA-CONTROL_BOARD-HK61EA006 Brand: Carrier
Guaranteed to fit PF4MNA042000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA006 for Model PF4MNA042000AAAA

This OEM fan blower control board is the factory-specified replacement for the Carrier PF4MNA042000AAAA air handler. The integrated fan control (IFC) board acts as the command center for your air handler — sequencing blower speeds, managing heat/cool delay timings, processing thermostat signals, and triggering fault protection lockouts. When it fails, symptoms typically include a blower that won't start, a system that runs continuously without responding to the thermostat, or a unit locked out with a flashing fault code that won't reset.

  • Specs: OEM Part Number HK61EA006 | Factory-matched fan blower control board | Direct drop-in replacement | Compatible with 24V control circuit | Designed for Carrier PF4MNA042000AAAA air handler
  • OEM vs Generic: This is a genuine OEM Carrier board with factory firmware, relay ratings, and terminal layout pre-matched to your unit. Aftermarket boards often require jumper reconfiguration, carry looser tolerances, and may not replicate all delay and fault-code logic — increasing the risk of nuisance lockouts or compressor short-cycling.
  • Install Difficulty: 3/5 — Intermediate skill level recommended. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone/camera for wiring photos. Always disconnect power at the breaker and verify 0V with a multimeter before handling the board. Photograph all wire connections before removal. Snap terminals in firmly and check for any DIP switch or jumper settings on the old board before discarding it.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse when ordered before cutoff.

Compatibility: Engineered specifically for the Carrier PF4MNA042000AAAA air handler. Always cross-reference the OEM part number HK61EA006 against your unit's data plate or existing board label before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — contact us and we'll confirm compatibility fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA042000AAAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA042000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA042000AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.