Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA036T00AAAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA036T00AAAA

SKU: CARRIE-PF4MNA036T00AAAA-CONTROL_BOARD-HK61EA006 Brand: Carrier
Guaranteed to fit PF4MNA036T00AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA006 for Model PF4MNA036T00AAAA

This is the OEM factory-specified fan blower control board for the Carrier PF4MNA036T00AAAA air handler. The control board serves as the command center for all blower motor operations — managing startup sequencing, fan speed staging, and the integrated time delay relay that governs how long the blower continues to run after a heating or cooling call ends. When this board fails, you may notice the blower fan refusing to start, running continuously without stopping, or delivering uneven airflow and inconsistent temperatures throughout the home. In some cases, a failed board causes the entire air handler to go non-responsive.

  • Specs: OEM Part# HK61EA006 | Cross-references: CEPL130541-01, 1171734, 103972, 122621, CPC E 94V-0, CEBD430541-10A, L45-229 | Integrated time delay relay | Factory-matched to Carrier PF4MNA036T00AAAA air handler
  • OEM vs Generic: This is the genuine OEM Carrier control board, not an aftermarket substitute. OEM boards are programmed and tested to exact factory specifications, ensuring precise relay timing and full compatibility with the unit's wiring harness — something generic boards frequently fail to replicate, leading to premature failures or error codes.
  • Install Difficulty: 3/5 — Power down the air handler at the breaker and disconnect the disconnect block before starting. Photograph all wiring connections before removing the old board. Transfer wires one at a time to the corresponding terminals on the new board. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, smartphone camera for reference photos.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PF4MNA036T00AAAA air handlers. Also cross-references part numbers CEPL130541-01, 1171734, 103972, and 122621 for applicable Carrier, Bryant, and Payne air handler platforms. Always verify your existing board's part number against your unit's data plate before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you buy — contact us today and get your system back up and running fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA036T00AAAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA036T00AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — PF4MNA036T00AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online