OEM Carrier Pressure Switch HK06WC061 for Model LC350TM400562

This is the genuine OEM pressure switch (part number HK06WC061) factory-specified for the Carrier LC350TM400562 furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor, confirming proper venting before allowing the control board to proceed with ignition. When this switch fails or becomes stuck open, the furnace will lock out before ever reaching the ignition stage — resulting in a no-heat call with the inducer running but no spark or gas flow. A failed pressure switch is one of the most common causes of furnace no-heat diagnostics in the field.

  • Specs: Factory-calibrated W.C. (water column) rating matched to Carrier LC350TM400562 | Single-port or dual-port configuration per OEM spec | 24V control circuit compatible | Direct hose and terminal connection — no modification required
  • OEM vs Generic: This is a genuine Carrier OEM part carrying the exact pressure threshold calibration for your unit. Aftermarket pressure switches often carry wider trip-point tolerances, which can cause nuisance lockouts or, worse, allow ignition under unsafe draft conditions.
  • Install Difficulty: 2/5 — Power down and verify inducer is off before servicing. Tools needed: 1/4" nut driver, flathead screwdriver, and a manometer to verify trip point after install. Inspect hose for cracks or blockages before replacing the switch — a clogged hose port is often the true culprit.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our HVAC parts warehouse.

Compatibility: Designed and calibrated specifically for the Carrier LC350TM400562 furnace. Always confirm the OEM part number HK06WC061 against your existing switch and verify the W.C. rating printed on the switch body before ordering. Our parts specialists are available to confirm fitment prior to purchase — no guesswork needed.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350TM400562?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350TM400562. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350TM400562?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.