OEM Carrier Pressure Switch HK06WC061 for Model LC350TM400558

This is the factory OEM replacement pressure switch (part number HK06WC061) for the Carrier LC350TM400558 furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor. It confirms that proper airflow and venting are established before allowing the control board to proceed with ignition. When this switch fails or sticks open, the furnace will lock out before the ignition sequence begins — leaving you with no heat and often a flashing fault code indicating a pressure switch error.

  • Specs: OEM-matched water column (W.C.) rating | Single-port or dual-port configuration as factory-specified | 24V control circuit compatible | Direct drop-in replacement for part number HK06WC061
  • OEM vs Generic: This is a genuine OEM Carrier pressure switch calibrated to the exact W.C. rating required for the LC350TM400558. Aftermarket switches frequently carry wide pressure tolerances that can cause nuisance lockouts or — more dangerously — allow ignition under unsafe draft conditions.
  • Install difficulty: 2/5 — Disconnect power before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a manometer if verifying W.C. reading. Always inspect the rubber hose and hose ports for cracks or blockages before replacing the switch, as a clogged port is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Carrier LC350TM400558 furnace. Verify the existing part number printed on your pressure switch matches HK06WC061 before ordering. If you are unsure, our parts specialists are available to confirm fitment using your model and serial number — just reach out before you order and we'll make sure you get the right part the first time.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350TM400558?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350TM400558. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350TM400558?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.