OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM pressure switch (part number HK06WC061) is the factory-specified replacement for the Carrier LC348TM402772 furnace. The pressure switch is a critical safety component that monitors the negative pressure generated by the inducer draft motor. Once the inducer reaches the correct airflow, the switch closes and signals the control board to proceed with the ignition sequence. A failed or stuck pressure switch will prevent the furnace from advancing past the inducer stage, resulting in a no-heat lockout condition — often indicated by a diagnostic fault code on the control board.
Compatibility: Designed specifically for the Carrier LC348TM402772 furnace. Always confirm the W.C. rating stamped on your existing switch matches this replacement before installation. If you are unsure of fitment, our HVAC parts specialists are available to verify compatibility before you order — ensuring you get the right part the first time. In stock and ships today.