OEM Carrier Pressure Switch HK06WC061 for LC348TM401746
Carrier

OEM Carrier Pressure Switch HK06WC061 for LC348TM401746

SKU: CARRIE-LC348TM401746-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit LC348TM401746 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch HK06WC061 for Model LC348TM401746

This OEM pressure switch (part number HK06WC061) is the factory-specified replacement for the Carrier LC348TM401746 furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor. When the inducer is running properly, the switch closes and signals the control board to proceed with ignition. A failed pressure switch will prevent the furnace from advancing past the inducer stage, resulting in a no-heat lockout condition — often indicated by a fault code on the control board or a rapidly blinking LED sequence.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) pressure rating | Single-port or dual-port configuration matched to Carrier LC348TM401746 specifications | 24V control circuit compatible
  • OEM vs Generic: This is a genuine OEM Carrier pressure switch, factory-calibrated to the exact water column rating required for safe, reliable ignition sequencing. Aftermarket substitutes frequently carry imprecise trip points, leading to nuisance lockouts, failed safety checks, or — more dangerously — ignition attempts under unsafe draft conditions.
  • Install difficulty: 2/5 — Disconnect power and gas before servicing. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers. Inspect the rubber hose connecting the pressure port to the inducer housing for cracks or blockages before installing the new switch, as a damaged hose is a common root cause of pressure switch failure.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Carrier LC348TM401746 furnace. Always verify the W.C. rating stamped on your existing pressure switch and cross-reference with part number HK06WC061 before ordering. Our HVAC parts specialists are available to confirm fitment prior to purchase. Order today and receive same-day shipping on all in-stock OEM Carrier parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC348TM401746?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC348TM401746. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC348TM401746?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online