OEM Carrier Draft Inducer Motor Capacitor for Model LC3:50HE400811

This is the factory-specified OEM run capacitor designed for the draft inducer motor assembly on the Carrier LC3:50HE400811 furnace. The draft inducer motor capacitor provides the electrical starting and running boost required to spin the inducer blower at the correct speed and torque. Without a properly functioning capacitor, the inducer motor may fail to start, run sluggishly, or trip the pressure switch — resulting in a no-heat lockout condition. If your furnace is failing to ignite, showing pressure switch fault codes, or you can hear the inducer humming but not spinning freely, this capacitor is a common and cost-effective first repair to perform before replacing the full inducer motor assembly.

  • Specs: OEM-matched MFD and voltage rating | Factory-specified round or oval run capacitor | Engineered for continuous duty inducer motor operation | Replaces OEM part numbers HC30CK235 and HC30CR230
  • OEM vs Generic: OEM capacitors are wound to exact factory tolerances (±5% or better), ensuring the inducer motor reaches proper RPM for reliable draft proving. Off-brand capacitors with loose tolerances can cause marginal operation, nuisance pressure switch lockouts, and premature motor bearing wear.
  • Install Difficulty: 2/5 — Disconnect power at the breaker and verify voltage is absent before beginning. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, multimeter (to verify capacitor is fully discharged). Photograph all wiring connections before removing the old capacitor. Match polarity and terminal labeling carefully.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship the same business day from our climate-controlled warehouse.

Compatibility: This capacitor is designed to fit the Carrier LC3:50HE400811 furnace draft inducer motor assembly, replacing OEM part numbers HC30CK235 and HC30CR230. Always confirm the MFD and voltage rating stamped on your existing capacitor or inducer motor label before ordering to ensure an exact match. Not sure if this is the right part? Contact our HVAC parts specialists — we verify fitment before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier LC3:50HE400811?
Yes. This is the factory-specified OEM capacitor for the Carrier LC3:50HE400811. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier LC3:50HE400811?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.