Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 410A Contactor 2-Pole 24V Coil for HP13PR04800GAKAA
Carrier

OEM Carrier 410A Contactor 2-Pole 24V Coil for HP13PR04800GAKAA

SKU: CARRIE-HP13PR04800GAKAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit HP13PR04800GAKAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model HP13PR04800GAKAA

This is the factory-specified OEM replacement contactor (part number HN51KC024) for the Carrier HP13PR04800GAKAA heat pump. The contactor is the high-voltage relay that receives a 24V signal from your thermostat and closes the circuit to deliver line voltage to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a burned coil, or a stuck plunger — the outdoor unit will not energize at all, or may run continuously without cycling off, leaving you with no heating or cooling.

  • Specs: 2-pole design | 24V control coil | Compatible with R-410A system electrical loads | Heavy-duty silver alloy contact tips rated for high-cycle operation
  • OEM vs Generic: OEM contactors like this HN51KC024 are built to Carrier's exact coil pull-in voltage and contact gap tolerances. Aftermarket contactors frequently use lower-grade contact alloys that pit faster under the high inrush current of a 4-ton compressor, leading to premature failure and potential compressor damage.
  • Install difficulty: 3/5 — Always shut off power at both the disconnect box and the breaker before servicing. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter (to verify coil voltage and contact continuity). Photograph all wiring connections before removal.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Engineered for the Carrier HP13PR04800GAKAA 4-ton single-stage heat pump. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — just reach out before you buy. Order today and your part ships the same business day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier HP13PR04800GAKAA?
Yes. This is the factory-specified OEM contactor for the Carrier HP13PR04800GAKAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier HP13PR04800GAKAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online