Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA010 for FX4CNB060000AAAA
OEM Carrier Fan Blower Control Board HK61EA010 for FX4CNB060000AAAA
OEM Carrier Fan Blower Control Board HK61EA010 for FX4CNB060000AAAA
OEM Carrier Fan Blower Control Board HK61EA010 for FX4CNB060000AAAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA010 for FX4CNB060000AAAA

SKU: CARRIE-FX4CNB060000AAAA-CONTROL_BOARD-HK61EA010 Brand: Carrier
Guaranteed to fit FX4CNB060000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA010 for Model FX4CNB060000AAAA

This is the factory OEM fan blower control board (part number HK61EA010) for the Carrier FX4CNB060000AAAA fan coil air handler. The integrated fan coil control (IFC) board serves as the central command center for your air handler — managing blower motor speed, cooling and heating calls from the thermostat, and all low-voltage control circuit logic. When this board fails, common symptoms include the blower not responding to thermostat calls, erratic or continuous blower operation, failure to energize the electric heat strips, or a completely unresponsive system with no activity at the air handler despite correct thermostat signals.

  • Specs: OEM Part Number HK61EA010 | Compatible with Carrier FX4CNB060000AAAA fan coil air handler | 24V control circuit input | Multi-speed blower motor control outputs | Factory-matched board layout for direct drop-in replacement
  • OEM vs Generic: This is a genuine OEM Carrier board manufactured to exact factory specifications. Generic or aftermarket control boards often lack proper motor speed calibration and surge protection, leading to premature blower motor failure and voided equipment warranties. OEM is always the safest choice for control boards.
  • Install Difficulty: 3/5 — Disconnect power at the breaker before beginning. Photograph or label all low-voltage wiring connections before removal. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, smartphone for wiring documentation. A multimeter is recommended to verify 24V input prior to board replacement to rule out transformer failure.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled warehouse.

Compatibility: Designed specifically for the Carrier FX4CNB060000AAAA fan coil air handler. Always verify the OEM part number HK61EA010 on your existing board's label before ordering to confirm an exact match. If you are unsure of fitment, our HVAC parts specialists are available to verify compatibility before you purchase — no guesswork required. In-stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier FX4CNB060000AAAA?
Yes. This is the factory-specified OEM control board for the Carrier FX4CNB060000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier FX4CNB060000AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online