Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF030010AFAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF030010AFAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF030010AFAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF030010AFAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF030010AFAA

SKU: CARRIE-FA4ANF030010AFAA-CONTROL_BOARD-HK61EA002 Brand: Carrier
Guaranteed to fit FA4ANF030010AFAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA002 for Model FA4ANF030010AFAA

This is the OEM factory-specified fan blower control board (part number HK61EA002) for the Carrier FA4ANF030010AFAA air handler. The blower control board serves as the command center for your air handler's indoor fan operation — managing blower motor speed, timing sequences, and communication with the thermostat and outdoor unit. When this board fails, common symptoms include the blower motor not starting, continuous or erratic fan operation, failure to respond to thermostat calls, or a complete system lockout with no heating or cooling airflow delivered to the living space.

  • Specs: OEM Part Number HK61EA002 | Factory-matched control logic for FA4ANF030010AFAA air handler | 24V control circuit compatible | Designed for multi-speed blower motor operation
  • OEM vs Generic: This is a genuine Carrier OEM board with factory-programmed timing and speed profiles specific to the FA4ANF030010AFAA. Aftermarket boards may use generic firmware that mismatches blower ramp-up timing and communicating thermostat protocols, leading to reduced comfort, efficiency, and potential motor damage over time.
  • Install difficulty: 3/5 — Requires disconnecting 120V and 24V wiring harnesses and documenting all connector positions before removal. Tools needed: Phillips and flathead screwdrivers, needle-nose pliers, smartphone (to photograph wiring), and a multimeter to confirm 24V supply is present. Always shut off power at the disconnect and breaker before servicing. If the unit is connected to a communicating thermostat system, verify board compatibility before powering on.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed by 3PM local time ship same business day from our climate-controlled parts warehouse.

Compatibility: Engineered as a direct OEM replacement for the Carrier FA4ANF030010AFAA fan coil air handler. Always cross-reference the part number on your existing board and the model/serial tag inside the unit before ordering to confirm fitment. Need help verifying compatibility? Our HVAC parts specialists confirm fitment before you buy — no guesswork, no return hassles.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier FA4ANF030010AFAA?
Yes. This is the factory-specified OEM control board for the Carrier FA4ANF030010AFAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier FA4ANF030010AFAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online