OEM Carrier Fan Blower Control Board HK61EA002 for Model FA4ANF018010AGAA

This is the factory-original Fan Blower Control Board (OEM part number HK61EA002) designed as a direct replacement for the Carrier FA4ANF018010AGAA air handler. The blower control board serves as the central command module for the air handler's indoor fan motor — managing blower speeds across all operational modes including cooling, heating, and continuous fan. When this board fails, symptoms typically include the blower failing to start, running at a single fixed speed regardless of demand, cycling on and off erratically, or triggering a complete system lockout with no airflow whatsoever. Replacing with a genuine OEM board ensures all factory-programmed blower profiles, timing delays, and fault diagnostics remain fully intact.

  • Specs: OEM Part Number HK61EA002 | Compatible voltage: 120V/240V | Factory-programmed multi-speed blower control | Includes diagnostic LED fault indication for simplified troubleshooting
  • OEM vs Generic: This is a genuine Carrier OEM board with pre-loaded factory firmware and timing parameters. Aftermarket boards frequently require manual dip-switch configuration, lack proper fault code support, and may not match the original blower motor's speed tap wiring — all of which can shorten motor life or void equipment warranties.
  • Install difficulty: 3/5 — Shut off all power at the disconnect and breaker before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, phone or camera to photograph all wiring harness connections prior to removal. Transfer wiring connectors one at a time to prevent miswiring. A multimeter is recommended to verify 24V control signal after installation.
  • Warranty: 1-year OEM manufacturer warranty. In-stock and ships same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier FA4ANF018010AGAA fan coil air handler. Always cross-reference the OEM part number HK61EA002 printed on your existing board's label before ordering to confirm fitment. Have questions about compatibility? Our HVAC parts specialists verify fitment before you order — call or chat today and get your system back up and running fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier FA4ANF018010AGAA?
Yes. This is the factory-specified OEM control board for the Carrier FA4ANF018010AGAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier FA4ANF018010AGAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.