Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF018000AGAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF018000AGAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF018000AGAA
OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF018000AGAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANF018000AGAA

SKU: CARRIE-FA4ANF018000AGAA-CONTROL_BOARD-HK61EA002 Brand: Carrier
Guaranteed to fit FA4ANF018000AGAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA002 for Model FA4ANF018000AGAA

This is the factory OEM fan blower control board (part number HK61EA002) for the Carrier FA4ANF018000AGAA air handler. The control board serves as the command center for all blower motor and fan operations — managing speed selection, timing sequences, and fault detection. When this board fails, you may experience a blower that won't run, a fan that operates at the wrong speed, erratic cycling behavior, or a complete system lockout with no response to thermostat calls. Replacing this board with the genuine OEM part restores factory-programmed logic and ensures compatibility with your existing wiring harness and components.

  • Specs: OEM Part Number HK61EA002 | Factory-programmed blower control logic | Compatible 24V control circuit input | Multi-speed fan coordination | Integrated fault detection and lockout reset
  • OEM vs Generic: OEM control boards ship with factory firmware and pre-configured timing delays, ensuring exact compatibility with your FA4ANF018000AGAA air handler. Aftermarket boards often require manual DIP-switch configuration and may not replicate all fault codes, leading to misdiagnosis and callbacks.
  • Install difficulty: 3/5 — Disconnect all power before beginning. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone or camera to photograph all wiring connections prior to removal. Transfer low-voltage wiring terminals carefully; a wiring error can damage the new board immediately upon power-up.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled parts warehouse.

Compatibility: Engineered specifically for the Carrier FA4ANF018000AGAA air handler. Always verify the OEM part number HK61EA002 on your existing board's label before ordering to confirm fitment. If you are unsure whether this board matches your unit, our HVAC parts specialists are available to verify compatibility before you purchase — no guesswork required.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier FA4ANF018000AGAA?
Yes. This is the factory-specified OEM control board for the Carrier FA4ANF018000AGAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier FA4ANF018000AGAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.